Target applications |
|
|
|
Hybrid electric and electric vehicles are the primary target applications. Electrodrive P03 320M360D-F is particularly suitable for direct drive applications in buses and small transport vehicles. Other applications include marine vehicles, machinery and wind power plant generators.
|
|
|
Specifications (Preliminary) |
|
|
Electrodrive P03 320M360D-F employs permeable pole cores and is provided with channels and integrated in/outlets for a cooling fluid.
Motor construction
| Radial
| Number of phases
| 3
| Commutation
| Electronic
| Type of EMF
| Sinusoidal
| |
| Rated torque 1, 3
| 320 Nm
| Peak torque 2, 3
| 1300 Nm
| Cogging torque
| < 0,5 Nm
| Torque ripple (sinusoidal EMF)
| < 2 %
| Rated speed
| 400 min-1
| Maximum speed
| 1300 min-1
| Rated power
| 13,4 kW
| |
| Diameter
| 360 mm
| Length 4
| 110 mm
| Mass
| 25 kg
| Moment of inertia
| 0,06 kgm2
| |
| Efficiency 5
| > 92 %
| Copper loss constant 5, 6
| 0,007 W(Nm)-2
| Core loss constant 5, 7
| 2,4 Ws2
| Torque constant K 5
| 0,4 Nm/W
| Temperature constant 8
| 0,001 K(Nm)-2
| Dynamic heat capacity
| 4,5 kJ/K
|
1
| Peak current density per phase jP = 10 A/mm2
| 2
| Peak current density per phase jP = 60 A/mm2
| 3
| RMS current density per phase equals 0,707 of peak current density for sinusoidal EMF.
| 4
| Casing not including shaft
| 5
| Motor only at rated operating parameters: Torque = 320 Nm, Speed = 400 min-1, Temperature = 60°C
| 6
| Copper loss in Watts is approximated by a product of copper loss constant and squared value of torque in Nm.
| 7
| Core loss in Watts is approximated by a product of core loss constant and squared value of speed in Hz.
| 8
| Employing liquid cooling
|
 P03 320M360D torque-current characteristics at stall |
|
|